Architectural 3D view of a timber-framed residential wall with window and door openings
Live 2D & 3D framing view

Free · No signup · IRC-compliant

Frame any wall. Cut list in 30 seconds.

IRC-compliant lumber estimates for studs, plates, headers and openings.
Free, sign up to save to the cloud, works on your phone at the lumber yard.

  • Studs, headers, plates & cripples counted automatically
  • Windows, doors & garage doors with IRC headers
  • 2D & 3D view, cost estimate, printable cut list

From measurements to materials

A framing plan you can actually build from.

01

Enter your wall

Length, height, interior or exterior, 16" or 24" O.C. — that's it.

02

Add openings

Drop in windows, doors and garage doors. Headers size themselves per IRC.

03

Get the cut list

Every board, board feet and a cost estimate — printable for the lumber yard.

Plan with fewer surprises

See every framing member before you buy a board.

Move from wall dimensions to a clear visual layout, code-aware headers, board feet, pricing and a printable cut list in one workspace.

  • Inspect the wall in accurate 2D or spatial 3D
  • Account for kings, jacks, headers, sills and cripples
  • Take a practical cut list and estimate to the lumber yard
Build your first wall
Sample wall plan Estimate ready
12'–0" WALL 16" O.C.
Studs
14
Board feet
98.7
Waste factor
10%

Ready when your measurements are

Turn the next wall into a confident material plan.

No spreadsheet, no signup, no guessing at the lumber rack.

Open the calculator

Frequently Asked Questions About Wall Framing

Answers to the most common questions about DIY wall framing, lumber calculations, and IRC building code requirements.

How many studs do I need for a 12-foot wall?

For a 12-foot wall with 16" O.C. stud spacing, you need approximately 10 studs (one every 16 inches plus end studs at each corner). With 24" O.C. spacing, you need about 7 studs.

If the wall has a window or door, add 2 king studs and 2 jack studs per opening. Use our calculator above—just enter your dimensions and it handles all the counting automatically.

What is the difference between 16" and 24" on-center stud spacing?

16" O.C. is the most common choice for load-bearing exterior walls. It provides greater rigidity, better drywall support, and is required in many jurisdictions for exterior framing.

24" O.C. uses fewer studs, reducing material cost by roughly 25%. It is acceptable per IRC for many interior non-load-bearing partition walls and some exterior configurations. Check your local building code before choosing 24" spacing for load-bearing applications.

What size header do I need for a window or door opening?

Header size depends on the span (opening width) and whether the wall is load-bearing:

  • Up to 3 ft: (2) 2×4 for roof/ceiling-only exterior bearing walls
  • 3–5 ft: (2) 2×6
  • 5–7 ft: (2) 2×8
  • 7–8 ft: (2) 2×10
  • 8–12 ft: Three-ply dimensional lumber or engineered lumber, depending on span and load

For 2×6 exterior walls, headers are typically built up with spacers or insulation to match wall thickness. For garage doors wider than 10 feet, a triple 2×12 or engineered LVL beam is typically required. Our calculator sizes headers automatically based on IRC R602.7 for its selected simplified load case.

What is the difference between a king stud, jack stud, and cripple stud?

King studs run the full height of the wall—from bottom plate to top plate—on each side of a window or door opening. They provide the primary lateral support for the opening.

Jack studs (also called trimmer studs) are shorter studs nailed inside the king studs. They run from the bottom plate to the underside of the header, directly bearing the header's load.

Cripple studs are short studs that fill in above and below openings at regular on-center spacing. Top cripples sit above the header; bottom cripples (sill cripples) support the rough window sill.

What lumber size do I use for load-bearing exterior walls?

Per IRC (International Residential Code), load-bearing exterior walls use 2×6 studs. This provides the structural capacity to carry roof and floor loads, and allows for R-19 or R-21 batt insulation.

Non-load-bearing exterior walls may use 2×4 studs, and interior partition walls standardly use 2×4 studs. If you're unsure whether your wall is load-bearing, consult a licensed structural engineer or your local building department.

How do I calculate board feet for a framing project?

The formula for board feet is: (thickness inches × width inches × length feet) ÷ 12.

For example, a 2×4 stud that is 8 feet long = (2 × 4 × 8) ÷ 12 = 5.33 board feet.

Our wall framing calculator totals board feet for every member automatically. When purchasing lumber, add 10–15% for waste from cuts and defects. Round stud counts up to the nearest whole number and plates up to standard lengths (8', 10', 12', 14', 16').

Do I need a building permit to frame a wall?

In most US jurisdictions, any structural framing work requires a building permit—including adding new walls, moving walls, or removing walls. Interior non-load-bearing partitions may be exempt in some cities or counties.

Requirements vary by location. Always contact your local building department before starting. Unpermitted work can cause complications during home sales, insurance claims, or future renovations.

What is the rough opening size for a window or door?

The rough opening (RO) is the framed opening—typically ½" to 1" wider and taller than the window or door unit to allow for shimming and leveling.

  • Windows: RO = unit width + ½" to 1" on each side; RO height = unit height + ½" to 1" on top and bottom.
  • Prehung interior doors: RO width = door width + 2" (for frame); RO height = door height + 2½".
  • Garage doors: RO = door width + 3"; RO height = door height + 1½" minimum.

Always check the window or door manufacturer's installation instructions for their specific rough opening requirements.